{"product_id":"ch-360t-mini-high-temperature-sterilizer","title":"CH-360T High-Temperature Sterilizer 2230ml","description":"\u003cp data-path-to-node=\"2\"\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=Lc4bIa_VtZA\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan class=\"_aupe copyable-text xkrh14z\"\u003eClick Here To Learn : HOW TO USE\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch1 data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eCH-360T High-Temperature Dry Heat Sterilizer\u003c\/b\u003e\u003c\/h1\u003e\n\u003ch3 data-path-to-node=\"3\"\u003e\u003cb data-path-to-node=\"3\" data-index-in-node=\"0\"\u003eUSER MANUAL\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"4\"\u003eThe CH-360T is a professional-grade dry heat sterilizer designed for compact workstations. By utilizing high-velocity thermal energy, it effectively eliminates 99.9% of bacteria and pathogens on metal tools. Unlike steam autoclaves, dry heat requires no routine cleaning of water tanks and will not dull your sharpest blades.\u003c\/p\u003e\n\u003chr data-path-to-node=\"5\"\u003e\n\u003ch2 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003e1. Technical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eModel:\u003c\/b\u003e CH-360T\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eMethod:\u003c\/b\u003e Dry Heat Sterilization (Thermal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eTemperature Range:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math=\"0^{\\circ}C - 200^{\\circ}C\" data-index-in-node=\"19\"\u003e$0^{\\circ}C - 200^{\\circ}C$\u003c\/span\u003e (\u003cspan class=\"math-inline\" data-math=\"392^{\\circ}F\" data-index-in-node=\"46\"\u003e$392^{\\circ}F$\u003c\/span\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eTimer Range:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math=\"0 - 60\" data-index-in-node=\"13\"\u003e$0 - 60$\u003c\/span\u003e Minutes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eVoltage:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math=\"220\\text{V} - 240\\text{V} ~ 50\/60\\text{Hz}\" data-index-in-node=\"9\"\u003e$220\\text{V} - 240\\text{V} ~ 50\/60\\text{Hz}$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003ePower:\u003c\/b\u003e \u003cspan class=\"math-inline\" data-math=\"300\\text{W}\" data-index-in-node=\"7\"\u003e$300\\text{W}$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003eInternal Material:\u003c\/b\u003e Mirror-finish Stainless Steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,7,0\"\u003e\u003cb data-path-to-node=\"7,7,0\" data-index-in-node=\"0\"\u003eExternal Material:\u003c\/b\u003e Powder-coated Iron (High-Heat Resistant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,8,0\"\u003e\u003cb data-path-to-node=\"7,8,0\" data-index-in-node=\"0\"\u003eChamber Dimensions:\u003c\/b\u003e Approx. \u003cspan class=\"math-inline\" data-math=\"25 \\times 12 \\times 6.5 \\text{ cm}\" data-index-in-node=\"28\"\u003e$25 \\times 12 \\times 6.5 \\text{ cm}$\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003ch2 data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003e2. Control Panel \u0026amp; Indicators\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul data-path-to-node=\"10\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,0,0\"\u003e\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003eTemperature Knob (Left):\u003c\/b\u003e Rotate to set the desired heat level (\u003cspan class=\"math-inline\" data-math=\"0^{\\circ}C\" data-index-in-node=\"63\"\u003e$0^{\\circ}C$\u003c\/span\u003e to \u003cspan class=\"math-inline\" data-math=\"200^{\\circ}C\" data-index-in-node=\"77\"\u003e$200^{\\circ}C$\u003c\/span\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,1,0\"\u003e\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eTimer Knob (Right):\u003c\/b\u003e Rotate to set the sterilization duration (\u003cspan class=\"math-inline\" data-math=\"0\" data-index-in-node=\"62\"\u003e$0$\u003c\/span\u003e to \u003cspan class=\"math-inline\" data-math=\"60\" data-index-in-node=\"67\"\u003e$60$\u003c\/span\u003e minutes).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,2,0\"\u003e\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eGreen Indicator (Power):\u003c\/b\u003e Lights up when the unit is connected and the timer is active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"10,3,0\"\u003e\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eRed Indicator (Heating):\u003c\/b\u003e Lights up when the internal heating element is actively warming the chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003ch2 data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003e3. Operating Instructions\u003c\/b\u003e\u003c\/h2\u003e\n\u003col start=\"1\" data-path-to-node=\"13\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,0,0\"\u003e\u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"0\"\u003ePrep:\u003c\/b\u003e Wash and \u003cb data-path-to-node=\"13,0,0\" data-index-in-node=\"15\"\u003ecompletely dry\u003c\/b\u003e all metal tools. Placing wet tools inside can cause oxidation or damage the heating element.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,1,0\"\u003e\u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"0\"\u003eLoading:\u003c\/b\u003e Place tools on the removable stainless steel tray. \u003cb data-path-to-node=\"13,1,0\" data-index-in-node=\"60\"\u003eDo not overlap\u003c\/b\u003e tools to allow the \u003cspan class=\"math-inline\" data-math=\"360^{\\circ}\" data-index-in-node=\"94\"\u003e$360^{\\circ}$\u003c\/span\u003e heat to circulate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,2,0\"\u003e\u003cb data-path-to-node=\"13,2,0\" data-index-in-node=\"0\"\u003eSeal:\u003c\/b\u003e Close the top lid firmly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,0\"\u003e\u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"0\"\u003eSet:\u003c\/b\u003e * Set the \u003cb data-path-to-node=\"13,3,0\" data-index-in-node=\"15\"\u003eTemperature Knob\u003c\/b\u003e (Recommended: \u003cspan class=\"math-inline\" data-math=\"180^{\\circ}C - 200^{\\circ}C\" data-index-in-node=\"46\"\u003e$180^{\\circ}C - 200^{\\circ}C$\u003c\/span\u003e).\u003c\/p\u003e\n\u003cul data-path-to-node=\"13,3,1\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,3,1,0,0\"\u003eSet the \u003cb data-path-to-node=\"13,3,1,0,0\" data-index-in-node=\"8\"\u003eTimer Knob\u003c\/b\u003e (Recommended: \u003cspan class=\"math-inline\" data-math=\"20 - 30\" data-index-in-node=\"33\"\u003e$20 - 30$\u003c\/span\u003e minutes).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,4,0\"\u003e\u003cb data-path-to-node=\"13,4,0\" data-index-in-node=\"0\"\u003eSterilize:\u003c\/b\u003e The Red light will come on. Once the target temperature is reached, the light may cycle on and off as the internal thermostat regulates the heat.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"13,5,0\"\u003e\u003cb data-path-to-node=\"13,5,0\" data-index-in-node=\"0\"\u003eCool Down:\u003c\/b\u003e When the timer dings, turn the temperature to zero. \u003cb data-path-to-node=\"13,5,0\" data-index-in-node=\"63\"\u003eWait at least 10 minutes\u003c\/b\u003e before opening. Use the included rings to lift the hot tray out.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr data-path-to-node=\"14\"\u003e\n\u003ch2 data-path-to-node=\"15\"\u003e\u003cb data-path-to-node=\"15\" data-index-in-node=\"0\"\u003e4. Recommended Heat Settings\u003c\/b\u003e\u003c\/h2\u003e\n\u003ctable data-path-to-node=\"16\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGoal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTime\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,0,0\"\u003e\u003cb data-path-to-node=\"16,1,0,0\" data-index-in-node=\"0\"\u003eDrying\/Warm-up\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"100^{\\circ}C\" data-index-in-node=\"0\"\u003e$100^{\\circ}C$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,1,2,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"10\" data-index-in-node=\"0\"\u003e$10$\u003c\/span\u003e Minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,0,0\"\u003e\u003cb data-path-to-node=\"16,2,0,0\" data-index-in-node=\"0\"\u003eStandard Sanitation\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"150^{\\circ}C\" data-index-in-node=\"0\"\u003e$150^{\\circ}C$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,2,2,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"20\" data-index-in-node=\"0\"\u003e$20$\u003c\/span\u003e Minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,0,0\"\u003e\u003cb data-path-to-node=\"16,3,0,0\" data-index-in-node=\"0\"\u003eTotal Sterilization\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,1,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"180^{\\circ}C - 200^{\\circ}C\" data-index-in-node=\"0\"\u003e$180^{\\circ}C - 200^{\\circ}C$\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"16,3,2,0\"\u003e\u003cspan class=\"math-inline\" data-math=\"30 - 45\" data-index-in-node=\"0\"\u003e$30 - 45$\u003c\/span\u003e Minutes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr data-path-to-node=\"17\"\u003e\n\u003ch2 data-path-to-node=\"18\"\u003e\u003cb data-path-to-node=\"18\" data-index-in-node=\"0\"\u003e5. Important Safety Warnings (Strict)\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul data-path-to-node=\"19\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,0,0\"\u003e\u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"0\"\u003eMETAL TOOLS ONLY:\u003c\/b\u003e \u003cb data-path-to-node=\"19,0,0\" data-index-in-node=\"18\"\u003eDO NOT\u003c\/b\u003e place plastic, wood, rubber-handled tools, or liquids inside. This unit will melt or ignite non-metal materials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,1,0\"\u003e\u003cb data-path-to-node=\"19,1,0\" data-index-in-node=\"0\"\u003eNO WATER:\u003c\/b\u003e This is a dry heat system. Never add water to the chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,2,0\"\u003e\u003cb data-path-to-node=\"19,2,0\" data-index-in-node=\"0\"\u003eHeat Hazard:\u003c\/b\u003e The exterior and the tray become extremely hot. Always use the pull-rings or heat-resistant gloves to handle the tray.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"19,3,0\"\u003e\u003cb data-path-to-node=\"19,3,0\" data-index-in-node=\"0\"\u003eVentilation:\u003c\/b\u003e Do not cover the vents on the sides of the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"20\"\u003e\n\u003ch2 data-path-to-node=\"21\"\u003e\u003cb data-path-to-node=\"21\" data-index-in-node=\"0\"\u003e6. Maintenance \u0026amp; Care\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul data-path-to-node=\"22\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,0,0\"\u003e\u003cb data-path-to-node=\"22,0,0\" data-index-in-node=\"0\"\u003eUnplug:\u003c\/b\u003e Always disconnect from the power outlet when not in use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,1,0\"\u003e\u003cb data-path-to-node=\"22,1,0\" data-index-in-node=\"0\"\u003eCleaning:\u003c\/b\u003e Once the unit is \u003cb data-path-to-node=\"22,1,0\" data-index-in-node=\"27\"\u003ecompletely cold\u003c\/b\u003e, wipe the stainless steel interior with a dry cloth to remove any residue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"22,2,0\"\u003e\u003cb data-path-to-node=\"22,2,0\" data-index-in-node=\"0\"\u003ePlacement:\u003c\/b\u003e Keep the unit away from flammable curtains or paper during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mask Queen Nepal","offers":[{"title":"Default Title","offer_id":52958158651708,"sku":null,"price":4500.0,"currency_code":"NPR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0739\/0681\/5292\/files\/rn-image_picker_lib_temp_b75b820a-602f-4e34-8a01-ed1401f2e1a6.png?v=1775457080","url":"https:\/\/maskqueenprofessional.com\/products\/ch-360t-mini-high-temperature-sterilizer","provider":"Mask Queen Nepal","version":"1.0","type":"link"}